| The MicrOclor design
incorporates all of the advantages of current industry standards
while radically improving all safety aspects of the process. |
|
0.8% sodium hypochlorite is produced on demand by
combining salt, water & electricity. |
|
 |
| The MicrOclor vertical
format allows for the instantaneous passive removal of all hydrogen
produced. |
| The state of the art patent
pending MicrOclor onsite hypochlorite generation system is a brand
new design built upon twenty years of dedicated research and
development in the field of onsite hypochlorite generation. |
| MicrOclor hypochlorite
systems meet requirements for 20 to 3000 pounds per day chlorine
equivalent and is modular in design and based on standard
components. These components may be customized to meet a wide range
of requirements. |
Applications include:
- Disinfection of potable water, wastewater, cooling towers,
and swimming pools.
- Odor and corrosion control.
- Oxidation.
|
|
Standard Components include:
- Water Softener
- Brine Tank
- Brine Pump
- Electrolytic Cells
- Wall Mount PLC Control Panel
- Power Supply
- Hypochlorite Storage Tank
- Hypochlorite Dosing Pump
- Hydrogen Dilution Blower
|
|
| The design incorporates all
of the advantages of current industry standards while radically
improving all safety aspects of the process. Specifically, the
manner in which hydrogen is removed from the electrolytic cell is a
huge improvement over more conventional tubular designs. |
| The MicrOclor vertical
format allows for the instantaneous passive removal of all hydrogen
produced. The recirculating nature of the MicrOclor design provides
for many benefits including reduced scaling potential, lower
resistance, lower heat gain, lower chlorate formation and higher
overall efficiencies. Further, PSI has perfected the ability to
monitor flow in each cell compartment versus the overall process. |
|
This ability to monitor compartmental flow when combined with the
passive hydrogen removal system precludes the possibility of
hydrogen entrapment. |
|
Redundant dynamic pressure transducers have been included into the
design and are fully capable of sensing a disruption in normal
operating conditions, such as a broken pipe or mistakenly closed
valve. |
| The MicrOclor design has
taken into account every imaginable failure scenario including
direct operator error in the handling of the process equipment. |
| Sequential operations logic
is provided for all process variables where the change from standby
to process is confirmed for all sensor locations at each start
sequence. This auto diagnostic routine locks out generation in the
event of sensor failure or electrical bypass. |
|
 |
|
|
|
|
|
|